Install a backer rod if necessary to maintain a consistent gap between the louver frame flange and ptac sleeve across the top and down both sides.
Ptac wall sleeve installation.
Power it on and test it.
When installing a ptac unit an anchored stable installation will improve performance and increase longevity.
It is the insta oohu vuhvsrqvlelolw to ensure there is adequate drainage for the ptac.
Install the sleeve and secure with mounting fasteners.
Summary the above is the basic steps to install a through the wall air conditioner sometimes call a window wall slide out air conditioner.
To ensure proper airflow and filter removal it is recom mended installation of the wall sleeve be a minimum of 36 from the ceiling.
Place the unit into the sleeve and screw it in place.
It s a good idea to frame the ptac unit with substantial secure wood studs.
Figure 4 minimum interior and exterior note.
Apply sealant to completely fill this pocket.
The sleeve will fit flush in the wall extending outside the structure.
While the dimensions may appear to be incompatible the 2 devices should fit properly.
Supporting and sealing sleeve to their frames.
Wall sleeve is secure and properly sealed to the wall.
Cooper and hunter 9 000 btu ptac packaged terminal air conditioner with heat pump pthp unit full set including steel installation sleeve and grille 5 0 out of 5 stars 1 1 055 00 1 055.
Caulk along the outside sleeve edges to prevent leaks.
The wall sleeve be installed a minimum of 36 from the ceiling.
Keys to proper installation.
If the sleeve projects more than 8 into the room a sub base or other means of support must be used.
In applications where the drain holes on the ptac wall sleeve are not exposed beyond the wall an internal drain system is recommended.
All wall and window wall installations must provide for proper drainage.
Air conditioner unit is centered in wall sleeve and sealed with foam pads to prevent air leakage.
Every scenario will be different with wall type and power always changing.
Sleeve must be tight against the bottom shim and fully bedded into sealant.
There is a portion of the air conditioner which extends a few inches back into the room.
Unit has a slight rearward slope within wall sleeve for proper drainage use tapered foam blocks.
Inches mm inches mm inches mm wall sleeve only 3 75 0 0 0 0 subbase kit 3 75 3 1 4 85 2 3 4 70.
The air conditioner will slide into the sleeve but is not flush with the wall.